What you need

Step 1

              Scanner Glass               
  • Open the top of the printer. The printer should appear as shown.

Open the top of the printer. The printer should appear as shown.

1024

Step 2

  • Use the blue plastic opening tool to pry the trim pieces all the way around the printer.
  • Loosen the pieces around the edges before pulling to remove from the printer.
  • Pull the (4) trim pieces off and set them aside.

Use the blue plastic opening tool to pry the trim pieces all the way around the printer.

Loosen the pieces around the edges before pulling to remove from the printer.

Pull the (4) trim pieces off and set them aside.

Step 3

  • Using the blue plastic opening tool, pull from the middle and then slide back to remove the side panels.
  • The side trim pieces need to be removed before the front trim pieces.

Using the blue plastic opening tool, pull from the middle and then slide back to remove the side panels.

The side trim pieces need to be removed before the front trim pieces.

Step 4

  • Using the T9 Torx Security screwdriver bit, unscrew the five 12mm screws shown.

Using the T9 Torx Security screwdriver bit, unscrew the five 12mm screws shown.

Step 5

  • The scanner flap is attached by a clip that can be dislodged by pulling it gently away from the printer.
  • Keeping the scanner flap upright, slide it toward the unattached clip in order to dislodge the second clip.
  • Both clips will come unattached and you can set the scanner flap aside.

The scanner flap is attached by a clip that can be dislodged by pulling it gently away from the printer.

Keeping the scanner flap upright, slide it toward the unattached clip in order to dislodge the second clip.

Both clips will come unattached and you can set the scanner flap aside.

Step 6

  • Lift the scanner glass piece from the printer.

Lift the scanner glass piece from the printer.

Step 7

  • The scanner glass is attached to the plastic piece with adhesive tape.
  • Pull off the glass and re-set new piece of glass.

The scanner glass is attached to the plastic piece with adhesive tape.

Pull off the glass and re-set new piece of glass.

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

                                                                                      One other person completed this guide.                                             

Author

                                      with 3 other contributors 

                    Laura                     

Member since: 10/23/2014

661 Reputation

                                      3 Guides authored                  



                       Badges:
                       12







                                                        +9 more badges                           

Team

                       Michigan Tech, Team 1-2, Lauer Fall 2014                        

                                                  Member of Michigan Tech, Team 1-2, Lauer Fall 2014 



                    MTU-LAUER-F14S1G2                     


                                            3 Members                     


                                            5 Guides authored